    Abstract
    For the medical linear accelerators (linac) that utilize more than 10 MV of photon energy, components inside the linac head become radioactivate during the 10–15-year operating cycle. Prior to disposal, radioactive waste must be evaluated for activity, and the same procedure should be followed for medical linacs. In the Republic of Korea, regulation and methodology for the radioactivity evaluation for the medical linac is not established yet. In this study, we employed gamma spectroscopy and a survey meter for evaluating the radioactivity of medical linac components. The components of the Siemens linac considered in this study were classified after decommissioning, and dose rates were measured to up to a 5 cm distance from the component surfaces by using a survey meter. Radionuclides from components were detected using an in situ HPGe detector. Based on the type of radionuclides and dose rate, we estimated the radioactivity of the components. We studied the feasibility of the methodology for disposing of radioactive components by using the in situ HPGe detector.

     

     

     

    Affiliations

    Na Hye Kwon1,2,† , Young Jae Jang3,4,† , Kum Bae Kim4,5 , Ji Hyun Yu6, Jinsung Kim 1,2,7, Dong Wook Kim
     1,2,*  and Sang Hyoun Choi4,5,*
     
    1
    Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
    2
    Medical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul 03722, Republic of Korea
    3
    Department of Accelerator Science, Korea University, Sejong 30015, Republic of Korea
    4
    Research Team of Radiological Physics & Engineering, Korea Institute of Radiological & Medical Sciences, Seoul 01812, Republic of Korea
    5
    Department of Radiation Oncology, Korea Institute of Radiological & Medical Sciences, Seoul 01812, Republic of Korea
    6
    R&D Institute, Sae-An Enertech Corp, Daejeon 34016, Republic of Korea
    7
    Oncosoft Inc., Seoul 03787, Republic of Korea
    *
    Authors to whom correspondence should be addressed.

    These authors contributed equally to this work.

  • 연구소개
    의료용 선형가속기의 폐기를 위한 적정한 절차 확립을 위한 HPGe 검출기의 활용과 관련한 연구논문입니다. 10 MV 이상의 광자 에너지를 사용하는 의료용 선형가속기의 헤드는 약 10~15년인 작동주기 동안 방사화하게 되는데, 안전한 폐기를 위한 방사능 평가를 위하여 실제 폐기되는 지멘스 치료기를 해체후 구성품에 따라 HPGe와 서베이미터를 사용하여 방사능을 측정 및 보고하였으며 HPGe 검출기를 사용하여 방사성 핵종을 파악하였습니다. 본 연구를 통하여 HPGe 검출기의 의료용 선형가속기의 폐기 절차에서의 활용 가능성과 방법론의 타당성을 제시하는 등, 의학물리분야에서 의료용 선형가속기 폐기에 대해 고민하는 많은 이들에게 도움이 될 만한 좋은 정보라 생각합니다.
  • 편집위원

    본 연구는 사용 후 폐기되는 치료용 선형가속기의 방사화 부품에 대한 규제기술을 개발하고자 하였음. HPGe를 이용하여 일렉타, 베리안, 지멘스 3사의 치료용 선형가속기의 각 부품에 대한 방사화를 측정하고 핵종을 분석하는 핵심 기술에 대하여 알 수 있어 가치가 높은 논문이라고 생각됨

    2023-02-06 15:53:13

  • 편집위원2

    지금까지 사용하던 선형가속기를 폐기할 때 별다른 측정이나 평가를하지 않았는데 고에너지 선형가속기를 10년 이상 사용했을 때 방사화가 어느 정도 되었는지 처음으로 평가를 해 보았다는 점에서 의미가 크다고 하겠다.

    2023-02-06 15:53:30

  • 덧글달기
    덧글달기
       IP : 3.128.203.143

    등록