의학물리학

본문글자크기
  • 2016년 01월호
    [J Nucl Med] MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method

    서울의대 / 안현준, 이재성*, 김유경*

  • 출처
    J Nucl Med
  • 등재일
    2015 Dec 23
  • 저널이슈번호
    pii: jnumed.115.163550. [Epub ahead of print]
  • 내용

    바로가기  >

    Abstract

    Inaccuracy in magnetic resonance image (MRI)-based attenuation correction (MR-AC) leads to errors in quantification and the misinterpretation of lesions in brain PET/MRI studies. To resolve this problem, we propose an improved ultrashort echo time (UTE) MR-AC method that is based on a multiphase level-set algorithm with B0 inhomogeneity correction. We also assessed the feasibility of this level-set-based MR-AC method (MR-AClevel), compared with CT-AC and MR-AC provided by the manufacturer of the PET/MRI scanner (MR-ACmMR).

     

    METHODS:

    Ten healthy volunteers and 20 Parkinson's disease patients underwent [18F]FDG and [18F]FP-CIT PET scans, respectively, using both PET/MRI and PET/CT scanners. The level-set-based segmentation algorithm automatically delimited air, bone, and soft tissue from the UTE MR images. For the comparison, MR-AC maps were coregistered to reference CT. PET sinogram data obtained from PET/CT studies were then reconstructed using the CT-AC, MR-ACmMR and MR-AClevel maps. The accuracies of SUV, SUVr and specific to nonspecific binding ratios (BR) obtained using MR-AClevel and MR-ACmMR were compared with CT-AC using ROI- and voxel-based analyses.

     

    RESULTS:

    There was remarkable improvement in the segmentation of air cavities and bones and the quantitative accuracy of PET measurement using the level set. While the striatal and cerebellar activities in [18F]FP-CIT PET and frontal activity in [18F]FDG PET were significantly underestimated by the MR-ACmMR, the MR-AClevel provided almost equivalent PET images to the CT-AC. PET quantification error was reduced by a factor of three using MR-AClevel (SUV error < 10% in MR-AClevel and < 30% in MR-ACmMR [version VB18P], and < 5% in MR-AClevel and < 15% in MR-ACmMR [VB20P]).

     

    CONCLUSION:

    The results of this study indicate that our new multiphase level-set-based MR-AC method improves the quantitative accuracy of brain PET in PET/MRI studies.

     

     

    Author information

    An HJ1, Seo S1, Kang H1, Choi H1, Cheon GJ1, Kim HJ1, Lee DS1, Song IC1, Kim YK2, Lee JS1.

    1 Seoul National University College of Medicine, Korea, Republic of;

    2 Seoul National University Bundang Hospital, Korea, Republic of. 

  • 키워드
    Correlative Imaging; Image Processing; PET/MRI; attenuation correction; brain PET; level-set segmentation
  • 덧글달기
    덧글달기
       IP : 3.135.219.78

    등록