  • [Phys Med Biol.] Dosimetric effect of internal metallic ports in temporary tissue expanders on postmastectomy radiation therapy: a Monte Carlo study.

    [Phys Med Biol.] Dosimetric effect of internal metallic ports in temporary tissue expanders on postmastectomy radiation therapy: a Monte Carlo study.

    이화의대 / 박종민, 김규보*

  • 출처
    Phys Med Biol.
  • 등재일
    2017 Jun 21
  • 저널이슈번호
    62(12):4623-4636. doi: 10.1088/1361-6560/aa700d. Epub 2017 Apr 28.
  • 내용

    바로가기  >


    Abstract

    To investigate the dosimetric effect of the internal metallic port (IMP) in a tissue expander (TE) on the dose distribution of postmastectomy radiation therapy (PMRT). A total of 10 patients who have received PMRT with a TE were selected retrospectively. For each patient, the dose distributions of treatment plans with a 10 MV photon beam were calculated using the Monte Carlo (MC) method with CT images. The dose distributions without the TE were also calculated by designating the mass densities of the TE including the IMP as those of tissue. From the MC calculations, the dose-volumetric parameters were calculated and analyzed for several structures: the planning target volume (PTV) including the TE, the PTV excluding the TE (PTVreal), the TE alone, heart, and lungs. For the PTV and PTVreal, dose-volumetric parameters did not appear to depend on the IMP. Within the TE volume, the maximum dose and D 1% were higher with the IMP than without the IMP (62.8  ±  1.4 Gy versus 57.9  ±  1.3 Gy with p  <  0.001 and 58.6  ±  1.6 Gy versus 57.0  ±  1.2 Gy with p  =  0.035). The values of V 100% and V 95% were lower with the IMP than without the IMP (77.9%  ±  7.6% versus 87.2%  ±  5.3% with p  =  0.008 and 89.5%  ±  5.6% versus 94.6%  ±  2.9% with p  =  0.027). The IMP did not affect dose-volumetric parameters of heart and lungs. Dosimetric changes due to the IMP occurred mainly within the TE, and not in the target volume, heart, and lungs.

     

    Author information

    Park JM1, Kim K, Park JI, Shin KH, Jin US, Kim JI.

    Department of Radiation Oncology, Seoul National University Hospital, Seoul 03080, Republic of Korea. Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea. Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea. Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon 16229, Republic of Korea. 

  • 연구소개
    본 연구는 조직확장기를 장착하고 Post mastectomy radiation therapy (PMRT)를 수행하는 환자에 대하여, 조직확장기의 금속포트가 처방 방사선량 분포에 미치는 영향을 조사한 연구이다. 임상적으로 유의미한 변화를 조사하기 위해 몬테카를로 전산모사 기법을 사용하여 10 명의 환자를 대상으로 체내 방사선량 분포를 계산하였다. 그 결과, 금속포트는 조직확장기 내 물질에 흡수되는 방사선량 분포를 변화시켰지만, 방사선치료 대상인 환자 조직에 대하여 방사선량 분포 변화를 발생시키지 않았다. 따라서, 기존에 알려진 연구와 달리, 조직확장기를 장착하고 PMRT를 수행할 경우에, 금속포트에 대한 고려를 할 필요가 없다는 것을 본 연구를 통해 확인하였다.
  • 편집위원

    방사선 치료의 30%를 차지하는 유방암 환자에 대한 연구 내용이므로 그 결과물의 효용성이 높습니다.