의학물리학

본문글자크기
  • 2017년 05월호
    [Phys Med Biol.] Hybrid charge division multiplexing method for silicon photomultiplier based PET detectors.

    서울의대/ 박해욱, 이재성*

  • 출처
    Phys Med Biol.
  • 등재일
    2017 Apr 3
  • 저널이슈번호
    62(11):4390-4405. doi: 10.1088/1361-6560/aa6aea. [Epub ahead of print]
  • 내용

    바로가기  >

    Abstract

    Silicon photomultiplier (SiPM) is widely utilized in various positron emission tomography (PET) detectors and systems. However, the individual recording of SiPM output signals is still challenging owing to the high granularity of the SiPM; thus, charge division multiplexing is commonly used in PET detectors. Resistive charge division method is well established for reducing the number of output channels in conventional multi-channel photosensors, but it degrades the timing performance of SiPM-based PET detectors by yielding a large resistor-capacitor (RC) constant. Capacitive charge division method, on the other hand, yields a small RC constant and provides a faster timing response than the resistive method, but it suffers from an output signal undershoot. Therefore, in this study, we propose a hybrid charge division method which can be implemented by cascading the parallel combination of a resistor and a capacitor throughout the multiplexing network. In order to compare the performance of the proposed method with the conventional methods, a 16-channel Hamamatsu SiPM (S11064-050P) was coupled with a 4  ×  4 LGSO crystal block (3  ×  3  ×  20 mm3) and a 9  ×  9 LYSO crystal block (1.2  ×  1.2  ×  10 mm3). In addition, we tested a time-over-threshold (TOT) readout using the digitized position signals to further demonstrate the feasibility of the time-based readout of multiplexed signals based on the proposed method. The results indicated that the proposed method exhibited good energy and timing performance, thus inheriting only the advantages of conventional resistive and capacitive methods. Moreover, the proposed method showed excellent pulse shape uniformity that does not depend on the position of the interacted crystal. Accordingly, we can conclude that the hybrid charge division method is useful for effectively reducing the number of output channels of the SiPM array.

     

    Author information

    Park H1, Ko GB, Lee JS.​

    1Department of Biomedical Sciences, Seoul National University College ofMedicine, Seoul 03080, Republic of Korea. Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 03080, Republic of Korea. 

  • 덧글달기
    덧글달기
       IP : 18.224.246.203

    등록