글로벌 연구동향
핵의학
- 2021년 05월호
[BMC Med Imaging.] Comparison of bone single-photon emission computed tomography (SPECT)/CT and bone scintigraphy in assessing knee joints아주의대 / 안영실*
- 출처
- BMC Med Imaging.
- 등재일
- 2021 Mar 26
- 저널이슈번호
- 21(1):60. doi: 10.1186/s12880-021-00590-8.
- 내용
Abstract
Background: This study attempted to compare the radiopharmaceutical uptake findings of planar bone scintigraphy (BS) and single photon emission computed tomography (SPECT)/computed tomography (CT) performed on knee joints.Methods: We retrospectively included 104 patients who underwent bone SPECT/CT and BS 4 h after the intravenous administration of technetium-99m-hydroxymethylene diphosphonate (99mTc-HDP) for pain in the knee joint. The uptake degree of each of the knee regions (medial femoral, lateral femoral, medial tibial, lateral tibial, and patellar area) in planar images and SPECT/CT were evaluated by visual (grades 0 to 2) and quantitative analyses (uptake counts for planar image and standardized uptake values [SUVs] for SPECT/CT).
Results: The uptake grades assessed visually on the planar images differed significantly from the uptake grades on SPECT/CT images in all areas of the knee (all p < 0.001), and SPECT/CT imaging revealed a larger number of uptake lesions than those noted in planar imaging for each patient (3.3 ± 2.0 vs 2.4 ± 2.3, p < 0.0001). In all regions of the knee, all of the quantitative values, including uptake counts obtained from the planar image as well as the maximum SUV (SUVmax) and mean SUV (SUVmean) obtained from SPECT/CT, showed statistically higher values as their visual grades increased (all p < 0.001). However, when analyzed for each area, only the SUVmax showed a significant difference by grade in all knee regions. Quantitative uptake values obtained from planar images were moderately correlated with SUVs of SPECT/CT images (r = 0.58 for SUVmean and r = 0.53 for SUVmax, all p < 0.001) in the total knee regions. Looking at each area, there was a significant but low correlation between the uptake counts of the planar images and the SUVs on SPECT/CT in the right lateral tibial region (r = 0.45 for SUVmean, r = 0.31 for SUVmax, all p < 0.001).
Conclusions: In assessing knee joints, the findings of planar images and SPECT/CT images differ both visually and quantitatively, and more lesions can be found in SPECT/CT than in the planar images. The SUVmax could be a reliable value to evaluate knee joint uptake activity.
Affiliations
Young-Sil An 1 , Do Young Park 2 , Byoung-Hyun Min 2 , Su Jin Lee 3 , Joon-Kee Yoon 3
1 Department of Nuclear Medicine and Molecular Imaging, School of Medicine, Ajou University, 206, World cup-ro, Yeongtong-gu, Suwon-si, Suwon, Gyeonggi-do, 16499, Korea. aysays77@naver.com.
2 Department of Orthopedic Surgery, Ajou University School of Medicine, Suwon, Korea.
3 Department of Nuclear Medicine and Molecular Imaging, School of Medicine, Ajou University, 206, World cup-ro, Yeongtong-gu, Suwon-si, Suwon, Gyeonggi-do, 16499, Korea.
- 키워드
- Bone scintigraphy; Knee joint; Quantitative evaluation; SPECT/CT; Single photon emission computed tomography/computed tomography; Standardized uptake value.
- 덧글달기
- 이전글 [Ann Nucl Med.] Test-retest reproducibility of dopamine transporter density measured with [ 18 F]FP-CIT PET in patients with essential tremor and Parkinson's disease
- 다음글 [Medicine (Baltimore).] Statin/ezetimibe combination therapy vs statin monotherapy for carotid atherosclerotic plaque inflammation