분자영상 및 방사화학

본문글자크기
  • 2016년 03월호
    [Theranostics] Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses.

    원광의대, 카이스트 / 박현*, 유경식*

  • 출처
    Theranostics
  • 등재일
    2016 Jan 1
  • 저널이슈번호
    6(2):231-42. doi: 10.7150/thno.14023. eCollection 2016.
  • 내용

    바로가기  >

    Abstract

    Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflective light collection module using a coumarin-derived dendrimer-based fluorescent lateral flow immunoassay. By application of an optimized bioconjugate, a smartphone-based diagnostic device had a two-fold higher detectability as compared to that of the table-top fluorescence strip reader for three different AI subtypes (H5N3, H7N1, and H9N2). Additionally, in a clinical study of H5N1-confirmed patients, the smartphone-based diagnostic device showed a sensitivity of 96.55% (28/29) [95% confidence interval (CI): 82.24 to 99.91] and a specificity of 98.55% (68/69) (95% CI: 92.19 to 99.96). The measurement results from the distributed individual smartphones were wirelessly transmitted via short messaging service and collected by a centralized database system for further information processing and data mining. Smartphone-based diagnosis provided highly sensitive measurement results for H5N1 detection within 15 minutes. Because of its high sensitivity, portability and automatic reporting feature, the proposed device will enable agile identification of patients and efficient control of AI dissemination. 

     

    Author information

    Yeo SJ1, Choi K2, Cuc BT1, Hong NN1, Bao DT1, Ngoc NM1, Le MQ3, Hang Nle K3, Thach NC3, Mallik SK4, Kim HS4, Chong CK5, Choi HS6, Sung HW7, Yu K2, Park H1.

    1. Zoonosis Research Center, Department of Infection Biology, School of Medicine, Wonkwang University, Iksan, 570-749, Republic of Korea.

    2. School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 305-338, Republic of Korea.

    3. National Institute of Hygiene and Epidemiology, No 1- Yersin street, Hanoi, Vietnam.

    4. College of Pharmacy, Institute of Pharmaceutical Research and Development, Wonkwang University, Iksan, 570-749, Republic of Korea.

    5. GenBody Inc, No.206, Biotech Business IC, DanKook University, San-29, Anseo-dong, Dongnam-gu, Cheonan, Republic of Korea.

    6. Division of Hematology/Oncology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston USA.

    7. College of Veterinary Medicine, Kangwon National University, Chunchon, 200-701, Republic of Korea. 

  • 키워드
    Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses
  • 덧글달기
    덧글달기
       IP : 3.142.130.250

    등록