    [Phys Med Biol] Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method

    연세의대 / 박광우, 박진호*, 박성호*, 최원훈*, 박석원*

  • 출처
    Phys Med Biol
  • 등재일
    2016 Jan 21
  • 저널이슈번호
    61(3):1293-1308. [Epub ahead of print]
  • 내용

    바로가기  >



    6MV X-ray빔에 대한, 반실험적 방식으로 얻은 작은 조사면에서의 교정계수.

    Abstract

    A semiempirical method based on the averaging effect of the sensitive volumes of different air-filled ionization chambers (ICs) was employed to approximate the correction factors for beam quality produced from the difference in the sizes of the reference field and small fields. We measured the output factors using several cylindrical ICs and calculated the correction factors using a mathematical method similar to deconvolution; in the method, we modeled the variable and inhomogeneous energy fluence function within the chamber cavity. The parameters of the modeled function and the correction factors were determined by solving a developed system of equations as well as on the basis of the measurement data and the geometry of the chambers. Further, Monte Carlo (MC) computations were performed using the Monaco® treatment planning system to validate the proposed method. The determined correction factors ([Formula: see text]) were comparable to the values derived from the MC computations performed using Monaco®. For example, for a 6 MV photon beam and a field size of 1  ×  1 cm2, [Formula: see text] was calculated to be [Formula: see text] for a PTW 31010 chamber and [Formula: see text] for a PTW 31016 chamber. On the other hand, the [Formula: see text] values determined from the MC computations were 1.121 and 1.031, respectively; the difference between the proposed method and the MC computation is less than 2%. In addition, we determined the [Formula: see text] values for PTW 30013, PTW 31010, PTW 31016, IBA FC23-C, and IBA CC13 chambers as well. We devised a method for determining [Formula: see text] from both the measurement of the output factors and model-based mathematical computation. The proposed method can be useful in case the MC simulation would not be applicable for the clinical settings.

     

    Author information

    Park K1, Bak J, Park S, Choi W, Park SW.

    1Department of Radiation Oncology, College of Medicine, Yonsei University, 134, Shinchon-Dong, Seodaemun-Gu, Seoul 120-740, Korea.

  • 연구소개
    비표준 조사면에서의 선량측정은 최근 10여년간의 노력에도 불구하고, 아직까지 확실한 프로토콜이 제안되지 않는 실정이다. 본 논문은 비표준 조사면, 특히 작은 조사면에서의 정확한 선량측정을 위하여, 작은 조사면이 만들어 내는 선질교정계수의 작은 변화를 재 교정하하는 교정 계수를, MC를 이용하지 않고, 반실험적 방식(수학적 모델 + 3개 챔버를 이용한 측정)으로 찾아내는 방법을 제안하는 논문이다.
  • 덧글달기
    덧글달기
       IP : 3.144.38.24

    등록