의학물리학

본문글자크기
  • [J Korean Med Sci] Radiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea.

    2016년 03월호
    [J Korean Med Sci] Radiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea.

    서울의대 / 권현우, 김종필, 팽진철*

  • 출처
    J Korean Med Sci
  • 등재일
    2016 Feb
  • 저널이슈번호
    31 Suppl 1:S69-74. doi: 10.3346/jkms.2016.31.S1.S69. Epub 2016 Feb 3.
  • 내용

    바로가기  >


    Abstract

    The purpose of this study was to estimate average radiation exposure from (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) examinations and to analyze possible factors affecting the radiation dose. A nation-wide questionnaire survey was conducted involving all institutions that operate PET/CT scanners in Korea. From the response, radiation doses from injected FDG and CT examination were calculated. A total of 105 PET/CT scanners in 73 institutions were included in the analysis (response rate of 62.4%). The average FDG injected activity was 310 ± 77 MBq and 5.11 ± 1.19 MBq/kg. The average effective dose from FDG was estimated to be 5.89 ± 1.46 mSv. The average CT dose index and dose-length product were 4.60 ± 2.47 mGy and 429.2 ± 227.6 mGy∙cm, which corresponded to 6.26 ± 3.06 mSv. The radiation doses from FDG and CT were significantly lower in case of newer scanners than older ones (P < 0.001). Advanced PET technologies such as time-of-flight acquisition and point-spread function recovery were also related to low radiation dose (P < 0.001). In conclusion, the average radiation dose from FDG PET/CT is estimated to be 12.2 mSv. The radiation dose from FDG PET/CT is reduced with more recent scanners equipped with image-enhancing algorithms. 

     

    Author information

    Kwon HW1, Kim JP2, Lee HJ2, Paeng JC3, Lee JS2, Cheon GJ3, Lee DS4, Chung JK3, Kang KW3.

    1Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.; Department of Molecular Medicine and Biopharmaceutical Science, Graduate school of Convergence Science and Technology, Seoul National University, Seoul, Korea.

    2Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea .

    3Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.; Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea.

    4Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.; Department of Molecular Medicine and Biopharmaceutical Science, Graduate school of Convergence Science and Technology, Seoul National University, Seoul, Korea.; Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul, Korea. 

  • 키워드
    Dose Reference Level; FDG PET/CT; National Survey; Radiation Exposure
  • 연구소개
    국내의 PET/CT 검사기관을 대상으로 FDG PET/CT 검사에 따른 선량을 조사한 설문조사 연구입니다. FDG 투여에 따른 유효선량의 평균치는 5.89 mSv 였고 CT scan에 따른 유효선량의 평균치는 6.26 mSv였습니다. 향후 국내에서 PET/CT 검사에 따른 선량을 확인하고 이를 바탕으로 dose reference level을 수립하는 데에 도움이 될 만한 정보라 생각합니다.
  • 덧글달기
    덧글달기
       IP : 18.117.113.186

    등록