의학물리학

본문글자크기
  • [Radiation Measurements] A small-scale realistic inter-laboratory accident dosimetry comparison using the TL/OSL from mobile phone components

    KAERI / 김형택*

  • 출처
    Radiation Measurements
  • 등재일
    2022 January
  • 저널이슈번호
    Volume 150, 106696
  • 내용

    바로가기  >

    Abstract
    An inter-laboratory comparison of a small-scale field experiment was conducted in the framework of the Korea retrospective dosimetry network (KREDOS) to verify the reliability and compatibility of thermoluminescence and optically stimulated luminescence techniques for accident dosimetry. Three institutes participated in this comparison, including the Korea Atomic Energy Research Institute, the Korea Institute of Nuclear Safety and the University of Salzburg. Two adult CIRS torso phantoms were used as virtual subjects exposed to a high-activity Ir-192 source, developing both homogeneous and inhomogeneous exposures in a shielded enclosure. The target materials for dose estimation were mobile phone components, such as resistors, display glasses, and chip cards. LiF:Mg,Cu, Si thermoluminescent (TL) detectors were used as reference dosimeters. The mobile phones were attached to the chest, hip, and thighs of the anthropomorphic phantoms. The measured doses ranged from 100 mGy to 2 Gy, depending on the position of the mobile phone on the phantom. The proficiency of the dose assessment was tested at three laboratories. Using the applied protocols, the local dose distribution on the display glasses was unclear, but the distribution around the body was confirmed.

     

     

    Affiliations

    Hyoungtaek Kim a,Hyungjoon Yub Michael Discher c, Min Chae Kim a d, Yoomi Choi a, Hyunseok Lee b, Jeong Tae Lee b, Hanjin Lee b, Young-su Kim a,Han Sung Kim e, Jungil Lee aa
    Korea Atomic Energy Research Institute, Daejeon, South Korea
    b
    Department of Radiological Emergency Preparedness, Korea Institute of Nuclear Safety, Daejeon, South Korea
    c
    Department of Geography and Geology, Paris-Lodron-University of Salzburg, Salzburg, Austria
    d
    Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea
    e
    National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea

  • 키워드
    Accident dosimetryThermoluminescence;Optically stimulated luminescence;Inter-laboratory comparison;Small-scale field experiment
  • 편집위원

    방사선사고 시 일반적인 관심사 중 하나인 피폭자의 선량 추정을 위하여, 일상생활 용품인 핸드폰을 이용하여 열발광 선량계(TLD) 및 광학 자극 발광 선량계(OSLD)가 없는 상황에서의 피폭선량을 추측하기위한 실험이 흥미로웠다.
    선량분석을 위하여, 동일한 측정 프로토콜을 사용하지만, 장비, 소스 교정, 샘플 추출, 신호 페이딩 등 측정된 신호에 대한 해석은 차이를 만들 수 있습니다. 본 논문에서는 다양한 기관과 협력하여 선량 분석을 위하여 긴밀한 네트워크를 형성하여 유의미한 결과를 도출한 것이 돋보입니다.

    2022-03-07 17:50:30

  • 덧글달기
    덧글달기
       IP : 3.145.115.195

    등록