  • [Phys Med Biol. ]  A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.

    2017년 02월호
    [Phys Med Biol. ] A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.

    서울의대/ 손정환, 이민선, 이재성*

  • 출처
    Phys Med Biol.
  • 등재일
    2017 Jan 21
  • 저널이슈번호
    62(2):465-483. doi: 10.1088/1361-6560/aa5076. Epub 2016 Dec 21.
  • 내용

    바로가기  >


    Abstract

    Positron emission tomography (PET) detectors with the ability to encode depth-of-interaction (DOI) information allow us to simultaneously improve the spatial resolution and sensitivity of PET scanners. In this study, we propose a DOI PET detector based on a stair-pattern reflector arrangement inserted between pixelated crystals and a single-ended scintillation light readout. The main advantage of the proposed method is its simplicity; DOI information is decoded from a flood map and the data can be simply acquired by using a single-ended readout system. Another potential advantage is that the two-step DOI detectors can provide the largest peak position distance in a flood map because two-dimensional peak positions can be evenly distributed. We conducted a Monte Carlo simulation and obtained flood maps. Then, we conducted experimental studies using two-step DOI arrays of 5  ×  5 Lu1.9Y0.1SiO5:Ce crystals with a cross-section of 1.7  ×  1.7 mm2 and different detector configurations: an unpolished single-layer (US) array, a polished single-layer (PS) array and a polished stacked two-layer (PT) array. For each detector configuration, both air gaps and room-temperature vulcanization (RTV) silicone gaps were tested. Detectors US and PT showed good peak separation in each scintillator with an average peak-to-valley ratio (PVR) and distance-to-width ratio (DWR) of 2.09 and 1.53, respectively. Detector PSRTV showed lower PVR and DWR (1.65 and 1.34, respectively). The configuration of detector PTAir is preferable for the construction of time-of-flight-DOI detectors because timing resolution was degraded by only about 40 ps compared with that of a non-DOI detector. The performance of detectors USAir and PSRTV was lower than that of a non-DOI detector, and thus these designs are favorable when the manufacturing cost is more important than timing performance. The results demonstrate that the proposed DOI-encoding method is a promising candidate for PET scanners that require high resolution and sensitivity and operate with conventional acquisition systems.

     

    Author information

    Son JW1, Lee MS, Lee JS.

    1Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea. Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul 110-744, Korea. 

     

     

  • 연구소개
    감마선에 대해 높은 민감도를 갖는 PET 장비를 위해서는 PET의 구성 요소인 섬광결정(scintillator)이 일정 이상의 길이를 가져야합니다. 이로 인해 PET 시야(field-of-view)의 중심에서 먼 영역의 해상도가 저하되는 문제점이 있습니다. 섬광결정 내에서 감마선의 반응 깊이(depth-of-interaction)를 측정할 수 있으면 위의 문제를 완화시킬 수 있습니다. 본 연구에서는 각 섬광결정 사이에 삽입하는 반사체의 패턴을 계단 모양으로 하되, 섬광결정의 깊이에 따라 반사체의 위치를 엇갈리게 하여, 감마선 반응 위치 히스토그램(2차원)으로부터 감마선의 반응 깊이(3차원)를 추정할 수 있는 방법을 제안하였습니다. 이 방법은 기존 PET 장비의 구성요소를 그대로 사용할 수 있고 깊이 추정 방법이 간단하기 때문에 추가적인 자원을 소모하지 않고 PET의 해상도 저하 문제를 해결할 수 있습니다.