핵의학

본문글자크기
  • [Radiology.] Maximum Standardized Uptake Value of 99mTc Hydroxymethylene Diphosphonate SPECT/CT for the Evaluation of Temporomandibular Joint Disorder.

    2016년 10월호
    [Radiology.] Maximum Standardized Uptake Value of 99mTc Hydroxymethylene Diphosphonate SPECT/CT for the Evaluation of Temporomandibular Joint Disorder.

    서울의대 / 서민석,이원우*

  • 출처
    Radiology.
  • 등재일
    2016 Sep
  • 저널이슈번호
    280(3):890-6. doi: 10.1148/radiol.2016152294. Epub 2016 Mar 31.
  • 내용

    바로가기  >


    그림. 정량적 SPECT/CTCT영상에서 TMJ주위로 volume-of-interest를 그리고 SPECT/CT영상에서 SUVmax를 구한다.


    Abstract

    Purpose To evaluate the diagnostic accuracy of the quantitative parameter standardized uptake value (SUV) at single photon emission computed tomography (SPECT)/computed tomography (CT) for the evaluation of temporomandibular joint (TMJ) disorder (TMD). Materials and Methods This study was approved by the institutional review board, and the need for informed consent was waived. Forty-four TMJs in 22 patients with TMD (five men and 17 women; mean age ± standard deviation, 30.0 years ± 12.1) were evaluated. The patients underwent planar bone scintigraphy and SPECT/CT 3-4 hours after injection of technetium 99m hydroxymethylene diphosphonate. The planar scintigraphy parameter of relative ratio (RR) and SPECT/CT parameters mean SUV (SUVmean) and maximum SUV (SUVmax) were compared for the visual assessment of TMD on planar scintigraphy images and for the presence of TMJ arthralgia. Group comparisons, receiver operating characteristic analysis, and Pearson correlation analysis were conducted. Results SUVmax gradually increased from normal (2.82 ± 0.73) to mild or moderately abnormal (3.56 ± 0.76, P < .05) and then to severely abnormal (4.86 ± 1.25, P < .05). However, RR and SUVmean did not vary significantly according to visual grade (P > .05). On the other hand, SUVmax was significantly greater in arthralgic TMJs (4.15 ± 1.11) than in nonarthralgic TMJs (2.97 ± 0.75, P < .001), as was SUVmean (1.63 ± 0.42 vs 1.30 ± 0.31, respectively; P = .005). However, there was no significant difference in RR (3.61 ± 0.57 vs 3.76 ± 0.68, P = .45). In receiver operating characteristic curve analyses for arthralgic TMJ, SUVmax had the greatest area under the curve (area of 0.815). Conclusion SUVmax derived from bone SPECT/CT may be useful for the evaluation of TMD.  

     

    Author information

    Suh MS1, Lee WW1, Kim YK1, Yun PY1, Kim SE1.

    1From the Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, South Korea (M.S.S., W.W.L., S.E.K.); Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul, South Korea (W.W.L.); and Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seoul, South Korea (Y.K.K., P.Y.Y.). 

  • 연구소개
    Tc-99m HDP 주사 후 정량적 단일광자방출전산화단층촬영/전산화단층촬영 (SPECT/CT)을 측두하악관절(temporomandibular joint, TMJ)주위에서 실시한 후에, 최대표준화섭취계수(maximum standardized uptake value, SUVmax)를 구하고 이렇게 구한 SUVmax가 측두하악관절질환(temporomandibular disorder, TMD)를 평가하는데 유용함을 보인 논문임.
  • 덧글달기
    덧글달기
       IP : 3.141.7.7

    등록