    The aim of this rat experiment using gamma correction pinhole bone scan (GCPBS) was two-fold: first, to confirm whether specific unwashed micro Tc-hydroxymethylene diphosphonate (Tc-HDP) uptake occurs in trabecular contusion (TC) and washed out uptake occurs in edema and/or hemorrhage-irritated trabeculae, and, second, to histopathologically identify the tissue in which the Tc-HDP uptake is unwashed. Five young Sprague-Dawley rats were used for the contusion model and one rat was used as a control. Trauma was inflicted on the femoral shaft with a free-falling iron ball. The presence of injury was confirmed by means of Tc-HDP pinhole bone scan and radiography with built-in scales. All rats were carefully killed for histopathologic verification. The size and shape of the unwashed high Tc-HDP uptake in TC were assessed on a 50-fold magnified GCPBS (mGCPBS), and the findings were compared with those of hematoxylin eosin (H&E) stain findings. mGCPBS showed TC with osteoblastic rimming and high unwashed Tc-HDP uptake. H&E stain findings showed osteoblastic rimming. The smallest TC was 0.03 mm in transaxial diameter on both mGCPBS and H&E stain findings. The four shapes of TC were bar-like, round, ovoid, and pinpointed in the longitudinal, oblique, and transaxial sections. The size and shape shown on mGCPBS and H&E stain findings were in good accord, demonstrating that TC was coated with osteoblastic rimming, which is pathognomonic of contusion. This sign was not seen for the control rat. mGCPBS is useful in the diagnosis of TC because osteoblastic rimming, typically stained in the base, is marked with unwashed high Tc-HDP uptake. 

     

    Author information

    Bahk YW1, Chung YA, Lee UY, Park SI.

    1aDepartment of Nuclear Medicine, Sung-Ae Hospital, Seoul bDepartment of Radiology cInstitute of Catholic Integrative Medicine (ICIM), Incheon St Mary's Hospital dDepartment of Anatomy, School of Medicine, The Catholic University of Korea, Seoul, South Korea. 

  • 연구소개
    가장 많이 시행되고 있는 뼈스캔의 새로운 임상적 유용성을 찾고자 연구한 내용입니다. 골절 및 골타박상 동물모델에서 뼈스캔 및 바늘구멍조준기로 영상을 얻고, 얻어진 영상을 감마교정으로 보정하여 골절과 골타박상을 감별하였고, 조직병리학적으로 증명하였습니다. 감마교정은 ACD see나 Photoshop 등의 프로그램에서 gamma correction 메뉴를 선택하여 감마교정 증가와 감소를 조절합니다. 그러면 섭취 정도가 변하면서 골절의 경우 강한 섭취가 남아있게 되고, 골타박상의 경우는 섭취가 사라지게 됩니다. 판독컴퓨터 등에서 빠르고 쉽게 적용이 가능하여 임상에 유용한 정보를 제공할 수 있을 것으로 생각합니다