글로벌 연구동향
방사선방호 및 안전
- 2025년 07월호
[J Environ Radioact .] A comparative evaluation of 222Rn sealing materials for 226Ra analysis by gamma spectrometry감마 분광분석을 통한 Ra-226 분석용 Rn-222 밀폐 재료의 비교 평가한국원자력안전기술원 / 서한창, 채정석*
- 출처
- J Environ Radioact .
- 등재일
- 2025 May:285:107673.
- 저널이슈번호
- 내용
Abstract
The accuracy of indirect measurements of 226Ra using gamma spectrometry critically depends on sealing techniques that prevent the escape of 222Rn (radon) generated within the sample. This study introduces a novel sealing method designed to overcome the limitations of conventional Rn sealing techniques. The Rn sealing performance of five sealing materials-silicone sealant, modified silicone sealant, butyl sealant, polyurethane sealant, and epoxy adhesive-was evaluated by sealing sample containers filled with Rn-containing water samples using each of the five materials, measuring Rn over time, and comparing experimentally estimated half-life of Rn for each sealed container with its physical half-life. Among the five sealing materials evaluated, the experimentally estimated half-life of Rn in samples sealed with modified silicone sealant, butyl sealant, polyurethane sealant, and epoxy adhesive, excluding silicone sealant, closely matched the physical half-life of Rn, demonstrating their reliable sealing performance. To verify the validity of the sealing method, the activity concentration of 226Ra was estimated in IAEA-434 phosphogypsum, a certified reference material, sealed with five different sealing materials. The results showed that for the four sealing materials, excluding silicone sealant, the measured values were statistically consistent with the certified value of IAEA-434, confirming the validity of the sealing method using these materials. The proposed sealing method enables accurate analytical results without requiring the complete filling of the measurement container, allows for visual inspection of the sample's filling state, and facilitates sample reuse for further analyses. These advantages make it a practical approach for the routine analysis of NORM and environmental samples.Affiliations
Han Chang Seo 1, Hyeon-Woo Lee 1, Kyeong Ho Kim 1, Jeongsoo Kang 1, Jung-Seok Chae 2
1Korea Institute of Nuclear Safety, 62 Gwahak-ro, Yuseong-gu, Daejeon, 34142, Republic of Korea.
2Korea Institute of Nuclear Safety, 62 Gwahak-ro, Yuseong-gu, Daejeon, 34142, Republic of Korea. Electronic address: jschae@kins.re.kr.
- 키워드
- (226)Ra analysis; Gamma spectrometry; Rn tightness; Sealing method; Secular equilibrium.
- 덧글달기
- 이전글 [Appl Radiat Isot .] Design of beam shaping assembly for 2.4 MeV electrostatic tandem accelerator-based neutron source for boron neutron capture therapy: A Monte Carlo study
- 다음글 [Radiation Measurements] Experimental Verification of Dual-Isotope Imaging of ²²⁵Ac/²¹³Bi for Targeted Alpha Therapy using Alpha Imaging Detector






편집위원
감마선 분광분석에서 Ra-226의 밀봉은 분석자들의 난제인데 논문에서 나온대로 구현이 된다면 자연방사능을 포함한 분석에서 실용적인 방법으로 사용하기 좋은 내용입니다.
덧글달기닫기2025-07-08 17:38:03
등록