[Appl Radiat Isot .] Neutron dose evaluation inside high-energy accelerator irradiation vault using LR-115LR-115를 이용한 고에너지 가속기 조사시설 내부 중성자 선량평가KIRAMS / 안윤진, 김상록*
- 출처
- Appl Radiat Isot .
- 등재일
- 2024 Sep:211:111403. doi: 10.1016/j.apradiso.2024.
- 저널이슈번호
- 내용
Abstract
Recently, a new radiation therapy using a high-energy accelerator irradiation vault has attracted significant attention. This therapy is very effective in destroying cancer cells because it uses much higher energy than conventional radiation therapy. Nevertheless, it also has disadvantages due to its high energy and dose, resulting in the generation of secondary radiation such as X-rays and neutrons. In particular, neutrons have a higher radiation weighting factor than photons; therefore, they are more harmful to normal tissues. However, the popular neutron dosimeter CR-39 cannot evaluate high-dose neutrons. This paper proposes a novel method for measuring high-dose neutrons generated during cancer treatment. LR-115, which has low detection efficiency but is expected to be useful for evaluating high-dose neutrons, was used to evaluate the effective dose of neutrons in a high-energy accelerator irradiation room. The results were verified using MCNP 6.2, a Monte Carlo-based particle transport code. This study provides the lower limit for evaluating neutron effective dose using LR-115. The experimental results showed that the neutron effective dose increased linearly with beam current. These findings provide basic data for evaluating neutron effective dose for radiation protection.Affiliations
Yunjin Ahn 1, Sangrok Kim 2, Suhyoung Lee 1
1Radiation Safety Section, Korea Institute of Radiological & Medical Sciences, Seoul, South Korea.
2Radiation Safety Section, Korea Institute of Radiological & Medical Sciences, Seoul, South Korea. Electronic address: kim@kirams.re.kr.
- 키워드
- High-energy accelerator; MCNP; Neutron effective dose; Radiation protection; Radiation therapy; Secondary radiation.
- 덧글달기






편집위원
암치료 중 발생하는 고선량 중성자를 측정하는 새로운 방법으로 중성자 유효선량 평가를 통해 인체를 방사선으로부터 보호할 수 있게끔하는데 활용도가 높아보임