방사선방호 및 안전

본문글자크기
  • 2024년 10월호
    [Radiation Measurements] Accuracy enhancement of L-band EPR tooth dosimetry by implementing multiple harmonic detection다중 harmonic detection 기반 L-밴드 EPR 치아 선량 측정의 정확도 향상 연구

    서울대 / 오정훈, 예성준*

  • 출처
    Radiation Measurements
  • 등재일
    August 2024
  • 저널이슈번호
    Volume 176 ,107185
  • 내용

    바로가기  >

    Abstract
    In a large-scale radiation accident, the swift classification of individuals exposed to high levels of radiation is crucial to minimize casualties. In-vivo tooth dosimetry using L-band electron paramagnetic resonance (EPR) spectroscopy is a promising method for this purpose, as it can estimate individual exposure levels rapidly and non-invasively. However, the accuracy of dose estimation associated with this technique remains a great challenge. To enhance the accuracy, digital multiple harmonic detection (MHD) was incorporated into a home-built L-band EPR spectrometer. This approach enabled the utilization of information present in higher harmonics of EPR signals, which has been often discarded in traditional EPR spectroscopy. Acquired multiple harmonic spectra were reconstructed to the first derivative spectrum to merge information and mitigate the signal broadening. The modulation amplitude varied in a range of 0.3–0.7 mT to maximize the accuracy. In a 0.5-min measurement at 0.6 mT, the standard error of inverse prediction (SEIP) was reduced to 0.57 Gy from 0.71 Gy. The statistical significancy of the enhancement was validated. In conclusion, the accuracy enhanced by this MHD can contribute to improving the efficiency of triage systems in the aftermath of a mass radiation accident.

     

    Jeonghun Oh a, Chang Uk Koo a, Jong In Park b, Kwon Choi c, Junyoung Lee a, Hiroshi Hirata d, Sung-Joon Ye c e f g

    a
    Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
    b
    Ionizing Radiation Metrology Group, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of Korea
    c
    Research Institute for Convergence Science, Seoul National University, Seoul, 08826, Republic of Korea
    d
    Division of Bioengineering and Bioinformatics, Faculty of Information Science and Technology, Hokkaido University, Sapporo 060–0814, Japan
    e
    Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
    f
    Advanced Institute of Convergence Technology, Seoul National University, Suwon, 16629, Republic of Korea
    g
    Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea

  • 키워드
    Retrospective dosimetryElectron paramagnetic resonanceIn vivoMultiple harmonic detection
  • 편집위원

    치아를 EPR로 분석하여 축적된 방사선량을 측정하는 것은 방사선사고 등에서 방사선 피폭량을 알 수 있는 방법으로 가치가 있는데, 이 논문에서는 EPR 신호중에서 사용하지 않던 하모닉 신호들를 이용하여 분석의 결과를 향상시키는 연구로 재미있었음

    덧글달기2024-10-04 15:48:45

  • 덧글달기
    덧글달기
       IP : 18.97.14.87

    등록