의학물리학

본문글자크기
  • [Phys Med Biol .] Material decomposition-based improved normalized metal artifact reduction method (MD-NMAR) in photon counting CT

    2025년 11월호
    [Phys Med Biol .] Material decomposition-based improved normalized metal artifact reduction method (MD-NMAR) in photon counting CT

    DIGIST / 남정현, 김준범, 예동해, 이옥균*

  • 출처
    Phys Med Biol .
  • 등재일
    2025 Aug 21
  • 저널이슈번호
    70(17).
  • 내용

    바로가기  >

    Abstract
    Photon counting computed tomography (PCCT) acquires multiple images of different energy ranges from a single computed tomography (CT) scan. It provides us with spatial and spectral information not available from conventional CT, making it possible for further analysis in the metal artifacts reduction (MAR). This study aims to develop a method to reduce metal artifacts in PCCT using material decomposition. We use the normalized MAR (NMAR) method and calibration data to obtain the initial basis material images. We correct the image of soft tissue using the NMAR and then correct the image of hard tissue by performing least squares fitting with virtual monochromatic images (VMIs). The artifact-reduced material images are reverted to the bin-wise images (CT images for each energy bin) and then employed as the improved prior images for the NMAR method to obtain the final MAR results: The metal artifact-reduced bin-wise CT images. In simulation results, the proposed method showed promising results, reducing metal artifacts compared to the original NMAR method applied to bin-wise images. For example, it reduced the root mean squared error values by an average of 6.3% for a dual-energy case. The proposed method also reproduced noticeable improvements in the table-top PCCT experiments compared to the conventional NMAR.

     

     

     

    Affiliations

    Jeonghyeon Nam 1, Joonbeom Kim 1, Dong Hye Ye 2, Okkyun Lee 1
    1Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu 42988, Republic of Korea.
    2Department of Computer Science, Georgia State University, Atlanta, GA 30303, United States of America.

  • 키워드
    material decomposition; normalized metal artifact reduction; photon counting CT; virtual monochromatic image.
  • 연구소개
    NMAR는 CT 영상에서 금속인공음영을 제거하는 기법 중 하나로 널리 사용되고 있습니다. 본 연구에서는 차세대 CT 시스템인 포톤카운팅 CT에서 물질분리를 이용하여 NMAR를 어떻게 효과적으로 적용할 수 있을지에 대한 새로운 방법론을 제시하였습니다: NMAR, 물질분리(forward), 각 기본 물질별 특성에 맞는 보정 수행, 물질분리(inverse), 그리고 마지막으로 NMAR를 다시 수행하여 기존의 방법들보다 에너지빈별로 효과적으로 금속인공음영을 제거하는 것을 시뮬레이션과 실제 실험 결과를 통해서 입증하였습니다.
  • 덧글달기
    덧글달기
       IP : 18.97.9.170