  • [J Appl Clin Med Phys.] Development of breast phantoms using a 3D printer and glandular dose evaluation 3D 프린터와 선량평가 방법을 이용한 유방 팬텀 개발

    부산가톨릭대 / 이동연, 양성희*

  • 출처
    J Appl Clin Med Phys.
  • 등재일
    2021 Oct
  • 저널이슈번호
    22(10):270-277. doi: 10.1002/acm2.13408. Epub 2021 Sep 16.
  • 내용

    바로가기  >

    Abstract
    In this study, breast phantoms were fabricated by emulating glandular and adipose tissues separately using a three-dimensional (3D) printer. In addition, direct and quantitative glandular dose evaluations were performed. A quantitative method was developed to evaluate the glandular and adipose tissues separately when performing glandular dose evaluations. The variables used for glandular dose evaluation were breast thickness, glandular tissue ratio, and additional filter materials. The values obtained using a Monte Carlo simulation and those measured using a glass dosimeter were compared and analyzed. The analysis showed that as the glandular tissue ratio increased, the dose decreased by approximately 10%, which is not a significant variation. The comparison revealed that the simulated values of the glandular dose were approximately 15% higher than the measured values. The use of silver and rhodium filters resulted in a mean simulated dose of 1.00 mGy and 0.72 mGy, respectively, while the corresponding mean measured values were 0.89 mGy ± 0.03 mGy and 0.62 mGy ± 0.02 mGy. The mean glandular dose can be reliably evaluated by comparing the simulated and measured values.

     

     

    Affiliations

    Dong-Yeon Lee  1 , Yong-In Jo  2 , Sung-Hee Yang  3
    1 Department of Radiological Science, College of Nursing, Health Sciences and Human Ecology, Dong-Eui University, Busan, Republic of Korea.
    2 Dongnam Institute of Radiological and Medical Sciences, Busan, Republic of Korea.
    3 Department of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea.

  • 키워드
    3D printer; breast phantom; glandular dose; glass dosimeter; simulation.
  • 편집위원

    위 논문은 Breast 영상 촬영 선량을 세밀하게 재현하여 측정할 수 있는 팬톰을 개발한 내용으로 유방암 검사시 조사 선량에 기인 할 수 있는 2차암 가능성을 연구를 위한 적절한 시도로 생각합니다.

    2021-12-06 16:04:40

  • 편집위원2

    최근 3D 프린팅 기술은 의료 분야에서 널리 활용되고 있다. 본 연구에서는 3D 프린터를 사용하여 유선조직과 지방조직을 별도로 모사하여 유방팬톰을 개발하여 유방 촬영술 중 유선조직의 선량을 직접 정량적으로 평가를 수행하였다. 개발된 유방 팬톰을 이용하여 몬테카를로 시뮬레이션으로 얻은 결과와 유리선량계를 이용한 측정값을 비교 분석하여 개발된 유방 팬톰의 신뢰도와 유효성을 검증하였다는 점에서 본 연구의 의의가 크다고 사료된다.

    2021-12-06 16:05:30