  • [Phys Med Biol.] Four-dimensional inverse-geometry computed tomography: a preliminary study

    [Phys Med Biol.] Four-dimensional inverse-geometry computed tomography: a preliminary study

    가톨릭의대, KAERI / 김경현, 서태석*, 김동수*

  • 출처
    Phys Med Biol.
  • 등재일
    2021 Mar 17
  • 저널이슈번호
    66(6):065028. doi: 10.1088/1361-6560/abe9f8.
  • 내용

    바로가기  >

    Abstract
    This study introduces and evaluates respiratory-correlated four-dimensional (4D) inverse geometry computed tomography (IGCT). The projection data of the IGCT were acquired in a single gantry rotation over 120 s. Three virtual phantoms-static Defrise, 4D Shepp-Logan, and 4D extended cardiac-torso (XCAT)-were used to obtain projection data for the IGCT and cone-beam computed tomography (CBCT). The projection acquisition parameters were determined to eliminate vacancies in the Radon space for an accurate rebinning process. Phase-based sorting was conducted within 10 phase bins, and the sorted projection data were binned into a cone beam geometry. Finally, Feldkamp-Davis-Kress reconstruction was conducted independently at each phase. The reconstructed images were compared using the structural similarity index measure (SSIM) and root mean square error (RMSE). The vertical profile of the Defrise reconstruction image was uniform, and the cone beam artefact was reduced in the IGCT image. Under an ideal projection acquisition condition, the mean coronal plane SSIMs of the Shepp-Logan and 4D XCAT phantoms were 0.899 and 0.706, respectively, which were higher than those of the CBCT (0.784 and 0.623, respectively). Similarly, the mean RMSEs of the coronal plane IGCT (0.036 and 0.158) exhibited an improvement over those of the CBCT (0.165 and 0.261, respectively). The mean standard deviations of the SSIM and RMSE were lower for IGCT than for CBCT. In particular, the SSIM and RMSE of the sagittal and coronal planes of the Shepp-Logan IGCT images were stable in all phase bins; however, those of the CBCT changed depending on the phase bins. Poor image quality was observed for IGCT under inappropriate conditions. This was caused by a vacancy in the Radon space, owing to an inappropriate scan setting. Overall, the proposed 4D IGCT exhibited better image quality than conventional CBCT.

     

     

     

     

    Affiliation

    Kyeong-Hyeon Kim  1 , Dong-Seok Shin, Sang-Won Kang, Seong-Hee Kang, Tae-Ho Kim, Jin-Beom Chung, Tae Suk Suh, Dong-Su Kim
    1 Department of Biomedical Engineering, Department of Biomedicine and Health Sciences, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

  • 연구소개
    기존의 Cone-beam computed tomography의 기하학적 한계를 보완한 Inverse-geometry computed tomography (IGCT)가 Linear accelerator (Linac)에 고정되어 있다는 조건에서 4차원 영상화에 대한 유용성을 평가한 논문입니다. 이는 Linac의 회전속도 제한에 따라 느린 갠트리 회전 조건 하에 4차원 IGCT영상화 시 발생할 수 있는 scan조건에 대한 고찰과 4차원 IGCT가 영상유도방사선치료에 적용 될 시 얻게 되는 Cone-beam artifact reduction, scan length확장 및 영상화질 증대가능성을 다루었습니다.