의학물리학

본문글자크기
  • [Phys Med Biol.] ICRP 메쉬형 표준팬톰 기반 백분위수별 팬톰 제작 연구Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    한양대 / 이한진, 김찬형*

  • 출처
    Phys Med Biol.
  • 등재일
    2019 Feb 5
  • 저널이슈번호
    64(4):045005. doi: 10.1088/1361-6560/aafcdb.
  • 내용

    바로가기  >

    Abstract
    Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advantages, including deformability which makes it possible to create phantoms in different body sizes or postures. In the present study, the MRCPs were deformed to produce a set of percentile-specific phantoms representing the 10th, 50th and 90th percentiles of standing height and body weight in Caucasian population. For this, anthropometric parameters for the percentile-specific phantoms were first derived from the anthropometric software and survey data. Then, the MRCPs were modified to match the derived anthropometric parameters. For this, first, the MRCPs were scaled in the axial direction to match the head height, torso length, and leg length. Then, the head, torso, and legs were scaled in the transversal directions to match the lean body mass for the percentile-specific phantoms. Finally, the scaled phantoms were manually adjusted to match the body weight and the remaining anthropometric parameters (upper arm, waist, buttock, thigh, and calf circumferences and sagittal abdominal diameter). The constructed percentile-specific phantoms and the MRCPs were implemented into the Geant4 Monte Carlo code to calculate organ doses for a cesium-137 contaminated floor. The results showed that organ doses of the 50th percentile (both standing height and body weight) phantoms are very close to those of the MRCPs. There were noticeable differences in organ doses, however, for the 10th and 90th percentile phantoms when compared with those of the MRCPs. The results of the present study confirm the general intuition that a small person receives higher doses than a large person when exposed to a static radiation field, and organs closer to the source receive higher doses.

     


    Author information

    Lee H1, Yeom YS, Nguyen TT, Choi C, Han H, Shin B, Zhang X, Kim CH, Chung BS, Zankl M.
    1
    Department of Nuclear Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea.

  • 덧글달기
    덧글달기
       IP : 18.223.106.232

    등록