방사선방호 및 안전

본문글자크기
  • [Nuclear Engineering and Technology] Implications of using a 50-μm-thick skin target layer in skin dose coefficient calculation for photons, protons, and helium ions

    한양대/염연수, 김찬형*

  • 출처
    Nuclear Engineering and Technology
  • 등재일
    13 June 2017
  • 저널이슈번호
  • 내용

    바로가기  >

    Abstract

    In a previous study, a set of polygon-mesh (PM)-based skin models including a 50-μm-thick radiosensitive target layer were constructed and used to calculate skin dose coefficients (DCs) for idealized external beams of electrons. The results showed that the calculated skin DCs were significantly different from the International Commission on Radiological Protection (ICRP) Publication 116 skin DCs calculated using voxel-type ICRP reference phantoms that do not include the thin target layer. The difference was as large as 7,700 times for electron energies less than 1 MeV, which raises a significant issue that should be addressed subsequently. In the present study, therefore, as an extension of the initial, previous study, skin DCs for three other particles (photons, protons, and helium ions) were calculated by using the PM-based skin models and the calculated values were compared with the ICRP-116 skin DCs. The analysis of our results showed that for the photon exposures, the calculated values were generally in good agreement with the ICRP-116 values. For the charged particles, by contrast, there was a significant difference between the PM-model-calculated skin DCs and the ICRP-116 values. Specifically, the ICRP-116 skin DCs were smaller than those calculated by the PM models?which is to say that they were underestimated?by up to ∼16 times for both protons and helium ions. These differences in skin dose also significantly affected the calculation of the effective dose (E) values, which is reasonable, considering that the skin dose is the major factor determining effective dose calculation for charged particles. The results of the current study generally show that the ICRP-116 DCs for skin dose and effective dose are not reliable for charged particles. 

     

    Yeon SooYeom, Thang TatNguyen, ChansooChoi, Min CheolHan, HanjinLee, HaeginHan, Chan HyeongKim

    Department of Nuclear Engineering, Hanyang University, 17 Haengdang, Seongdong, Seoul 133?791, South Korea 

  • 키워드
    ICRP Reference Voxel PhantomMonte CarloPolygonal-MeshSkin Dose CoefficientSkin Target Layer
  • 편집위원

    - 본 논문은 2017년 7월 Nuclear Engineering and Technology에 실린 논문으로 ICRP voxel phantom을 기반으로 계산된 피부선량(skin dose coefficients, skin DCs)값을 새롭게 제작된 폴리곤 면 기반 모의피폭체를 사용하여 새롭게 평가한 논문이다.
    - 본 논문은 ICRP에서 권고하는 피부선량이 평가 되어야 할 위치, 즉 skin target layer(피부 표면으로부터 50 um 깊이의 50 um 두께)를 폴리곤 면 기반 모의피폭체에 구현하였으며, 해당 위치에서 다양한 방사선(광자, 양성자 및 헬륨이온)을 기반으로 한 skin DCs값을 계산 하였다.
    - 최종적으로 skin DCs값을 ICRP 116에서 제공하고 있는 reference 값과 비교함으로서 폴리곤면 기반 모의피체의 skin DCs 값의 유효성이 검증되었고, 특히 1~10 MeV 방사선에 의한 피부선량을 더욱 정확하고 정밀하게 평가하였다.
    - 본 논문은 기존에 잘못 계산되었던 skin DCs값을 더욱 정밀하게 정확하게 계산하였으며, 새로운 skin DCs 기준값을 제시함으로서 피부선량 평가에 대한 새로운 기준점을 제공하고 있는 논문으로 생각된다.

    2017-07-18 14:21:04

  • 덧글달기
    덧글달기
       IP : 3.19.56.45

    등록