    Abstract
    The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.

     

     

    Myeongsoo Kim1,†, Ui-Jung Hwang2,†, Kyeongyun Park1, Dohyeon Kim1 , Hak Soo Kim1 , Sang Hyoun Choi3 , Jong Hwi Jeong1, Dongho Shin1, Se Byeong Lee1, Joo-Young Kim1, Tae Hyun Kim1 , Hye Jung Baek4, Hojin Kim5, Kihwan Kim2, Sang Soo Kim4,*  and Young Kyung Lim1,*
    1
    Department of Radiation Oncology, Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
    2
    Department of Radiation Oncology, College of Medicine, Chungnam National University, Daejeon 35015, Korea
    3
    Department of Radiation Oncology, Korea Cancer Center Hospital, Seoul 01812, Korea
    4
    Radiological Science Branch, Research Institute, National Cancer Center, Goyang 10408, Korea
    5
    Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul 03722, Korea
    *
    Authors to whom correspondence should be addressed.

    These authors contributed equally to this work.

     

     

  • 키워드
    spatially fractionated radiation therapy; proton therapy; proton minibeam radiation therapy; multislit collimator; scatterer; peak-to-valley dose ratio
  • 덧글달기
    덧글달기
       IP : 3.144.35.148

    등록