의학물리학

본문글자크기
  • [Med Dosim.] Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques.

    을지대 / 김성진, 윤선민*

  • 출처
    Med Dosim.
  • 등재일
    2018 Spring
  • 저널이슈번호
    43(1):55-68. doi: 10.1016/j.meddos.2017.08.003. Epub 2017 Oct 5.
  • 내용

    바로가기  >

    Abstract
    The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V95%, V105%, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and VXGy, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p < 0.05). For PTV dose distribution, IMRT showed increases of approximately 1.2% in Dmean and of approximately 5.7% in V95% dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in Dmean and V95%. IMRT was the best in terms of conformity index and homogeneity index (p < 0.05), whereas 3DCRT and VMAT did not significantly differ from each other. In terms of dose distribution on lungs, heart, and liver, the percentage of volume at high doses such as V30Gy and V40Gy was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V5% and V10%, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.

     


    Author information

    Kim SJ1, Lee MJ2, Youn SM3.
    1
    Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea; Department of Physics, Yeung Nam University, Daegu, Republic of Korea.
    2
    Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea.
    3
    Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea. Electronic address: smyoun@eulji.ac.kr.

  • 키워드
    3DCRT; IMRT; Synchronous bilateral breast cancer; VMAT
  • 덧글달기
    덧글달기
       IP : 3.230.1.23

    등록